    NAME

    cfgadm_scsi - SCSI hardware specific commands for cfgadm
     
    

    SYNOPSIS

    /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option]
        -c function ap_id...
    

    /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option]
        -x hardware_function ap_id...
    

    /usr/sbin/cfgadm [-v] [-a] [-s listing_option] [-o hardware_option]
        [-l [ap_id | ap_type ... ]]
    

    /usr/sbin/cfgadm [-v] [-o hardware_option] -t ap_id...
    

    /usr/sbin/cfgadm [-v] [-o hardware_option] -h [ap_id]...
    

     

    DESCRIPTION

    The SCSI hardware specific library /usr/lib/cfgadm/scsi.so.1 provides the functionality for SCSI hot-plugging through the cfgadm(1M) command. cfgadm operates on attachment points, which are locations in the system where hardware resources can be dynamically reconfigured. Refer to cfgadm(1M) for information regarding attachment points.

    For SCSI hot-plugging, each SCSI controller is represented by an attachment point in the device tree. In addition, each SCSI device is represented by a dynamic attachment point. Attachment points are named through ap_ids. Two types of ap_ids are defined: logical and physical. The physical ap_id is based on the physical pathname, whereas the logical ap_id is a shorter more user-friendly name. For SCSI controllers, the logical ap_id is usually the corresponding disk controller number. For example, a typical logical ap_id would be c0.

    SCSI devices are named relative to the controller ap_id. Thus if a disk device is attached to controller c0, its ap_id can be:

    c0::dsk/c0t0d0
    

    where dsk/c0t0d0 identifies the specific device. In general, the device identifier is derived from the corresponding logical link for the device in /dev. For example, a SCSI tape drive logical ap_id could be c0::rmt/0. Here c0 is the logical ap_id for the SCSI controller and rmt/0 is derived from the logical link for the tape drive in /dev/rmt. If an identifier can not be derived from the link in /dev, a unique identifier will be assigned to it. For example, if the tape device has no link in /dev, it can be assigned an ap_id of the form c0::st3 where st3 is a unique internally generated identifier.

    A simple listing of attachment points in the system will include attachment points at SCSI controllers but not SCSI devices. Use the -a flag to the list option (-l) to list SCSI devices as well. For example:

    # cfgadm -l
     Ap_Id             Type        Receptacle     Occupant     Condition
     c0                scsi-bus    connected      configured   unknown
     sysctrl0:slot0    cpu/mem     connected      configured   ok
     sysctrl0:slot1    sbus-upa    connected      configured   ok
    

    To list SCSI devices in addition to SCSI controllers:

    # cfgadm -al
    
    Ap_Id                Type         Receptacle   Occupant     Condition
    c0                   scsi-bus     connected    configured   unknown
    c0::dsk/c0t14d0      disk         connected    configured   unknown
    c0::dsk/c0t11d0      disk         connected    configured   unknown
    c0::dsk/c0t8d0       disk         connected    configured   unknown
    c0::dsk/c0t0d0       disk         connected    configured   unknown
    c0::rmt/0            tape         connected    configured   unknown
    sysctrl0:slot0       cpu/mem      connected    configured   ok
    sysctrl0:slot1       sbus-upa     connected    configured   ok
    

    Refer to cfgadm(1M) for more information regarding listing attachment points. The receptacle and occupant state for attachment points at the SCSI controller have the following meanings:

    empty

    not applicable

    disconnected

    bus quiesced (I/O activity on bus is suspended)

    connected

    bus active

    configured

    one or more devices on the bus is configured

    unconfigured

    no device on the bus is configured

    The corresponding states for individual SCSI devices are:

    empty

    not applicable

    disconnected

    bus to which the device is attached is quiesced

    connected

    bus to which device is attached is active

    configured

    device is configured

    unconfigured

    device is not configured

     

    OPTIONS

    cfgadm defines several types of operations besides listing (-l).These operations include testing, (-t), invoking configuration state changes, (-c), invoking hardware specific functions (-x), and obtaining configuration administration help messages (-h).

    -c function

    The following generic commands are defined for the SCSI hardware specific library:

    For SCSI controller attachment points, the following configuration state change operations are supported:

    connect

    Unquiesce the SCSI bus.

    disconnect

    Quiesce the bus (suspend I/O activity on bus).

    Incorrect use of this command can cause the system to hang. See NOTES.

    configure

    Configure new devices on SCSI bus.

    unconfigure

    Unconfigure all devices connected to bus.

    The following generic commands are defined for SCSI devices:

    configure

    configure a specific device

    unconfigure

    unconfigure a specific device

    -f

    When used with the disconnect command, forces a quiesce of the SCSI bus, if supported by hardware.

    Incorrect use of this command can cause the system to hang. See NOTES.

    -h ap_id

    SCSI specific help can be obtained by using the help option with any SCSI attachment point.

    -o hardware_option

    No hardware specific options are currently defined.

    -s listing_option

    Attachment points of class scsi can be listed by using the select sub-option. Refer to the cfgadm(1M) man page for additional information.

    -t ap_id

    No test commands are available at present.

    -x hardware_function

    Some of the following commands can only be used with SCSI controllers and some only with SCSI devices.

    In the following, controller_ap_id refers to an ap_id for a SCSI controller, for example, c0. device_ap_id refers to an ap_id for a SCSI device, for example: c0::dsk/c0dt3d0.

    The following hardware specific functions are defined:

    insert_device controller_ap_id

    Add a new device to the SCSI controller, controller_ap_id.

    This command is intended for interactive use only.

    remove_device device_ap_id

    Remove device device_ap_id.

    This command is intended for interactive use only.

    replace_device device_ap_id

    Remove device device_ap_id and replace it with another device of the same kind.

    This command is intended for interactive use only.

    reset_device device_ap_id

    Reset device_ap_id.

    reset_bus controller_ap_id

    Reset bus controller_ap_id without resetting any devices attached to the bus.

    reset_all controller_ap_id

    Reset bus controller_ap_id and all devices on the bus.

    locator [=on|off] device_ap_id

    Sets or gets the hard disk locator LED, if it is provided by the platform. If the [on|off] suboption is not set, the state of the hard disk locator is printed.

    led[=LED,mode=on|off|blink] device_ap_id

    If no sub-arguments are set, this function print a list of the current LED settings. If sub-arguments are set, this function sets the mode of a specific LED for a slot.

     

    EXAMPLES

    Example 1 Configuring a Disk

    The following command configures a disk attached to controller c0:

    # cfgadm -c configure c0::dsk/c0t3d0
    

    Example 2 Unconfiguring a Disk

    The following command unconfigures a disk attached to controller c0:

    # cfgadm -c unconfigure c0::dsk/c0t3d0
    

    Example 3 Adding a New Device

    The following command adds a new device to controller c0:

    # cfgadm -x insert_device c0
    

    The system responds with the following:

    Adding device to SCSI HBA: /devices/sbus@1f,0/SUNW,fas@e,8800000
    This operation will suspend activity on SCSI bus c0
    Continue (yes/no)? 
    

    Enter:

    y
    

    The system responds with the following:

    SCSI bus quiesced successfully. 
    It is now safe to proceed with hotplug operation.
    Enter y if operation is complete or n to abort (yes/no)?
    

    Enter:

    y
    

    Example 4 Replacing a Device

    The following command replaces a device attached to controller c0:

    # cfgadm -x replace_device c0::dsk/c0t3d0
    

    The system responds with the following:

    Replacing SCSI device: /devices/sbus@1f,0/SUNW,fas@e,8800000/sd@3,0
    This operation will suspend activity on SCSI bus: c0
    Continue (yes/no)?
    

    Enter:

    y
    

    The system responds with the following:

    SCSI bus quiesced successfully. 
    It is now safe to proceed with hotplug operation.
    Enter y if operation is complete or n to abort (yes/no)?
    

    Enter:

    y
    

    Example 5 Encountering a Mounted File System While Unconfiguring a Disk

    The following command illustrates encountering a mounted file system while unconfiguring a disk:

    # cfgadm -c unconfigure c1::dsk/c1t0d0
    

    The system responds with the following:

    cfgadm: Component system is busy, try again: failed to offline:
    /devices/pci@1f,4000/scsi@3,1/sd@1,0
        Resource              Information
    ------------------  --------------------------
    /dev/dsk/c1t0d0s0   mounted filesystem "/mnt"
    

    Example 6 Display the Value of the Locator for a Disk

    The following command displays the value of the locator for a disk. This example is specific to the SPARC Enterprise Server family:

    # cfgadm -x locator c0::dsk/c0t6d0
    

    The system responds with the following:

    Disk                    Led
    c0t6d0                  locator=on
    

    Example 7 Set the Value of the Locator for a Disk

    The following command sets the value of the locator for a disk. This example is specific to the SPARC Enterprise Server family:

    # cfgadm -x locator=off c0::dsk/c0t6d0
    

    The system does not print anything in response.

     

    FILES

    /usr/lib/cfgadm/scsi.so.1

    hardware-specific library for generic SCSI hot-plugging

    /usr/platform/SPARC-Enterprise/lib/cfgadm/scsi.so.1

    platform-specific library for generic SCSI hot-plugging

     

    ATTRIBUTES

    See attributes(5) for descriptions of the following attributes:

    ATTRIBUTE TYPEATTRIBUTE VALUE

    AvailabilitySUNWcsl

     

    SEE ALSO

    cfgadm(1M), luxadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5)  

    NOTES

    The disconnect (quiesce) operation is not supported on controllers which control disks containing critical partitions such as root (/), /usr, swap, or /var. The disconnect operation should not be attempted on such controllers. Incorrect usage can result in a system hang and require a reboot.

    When a controller is in the disconnected (quiesced) state, there is a potential for deadlocks occurring in the system. The disconnect operation should be used with caution. A controller should be kept in the disconnected state for the minimum period of time required to accomplish the DR operation. The disconnect command is provided only to allow the replacement of the SCSI cables while the system is running. It should not be used for any other purpose. The only fix for a deadlock (if it occurs) is to reboot the system.

    Hotplugging operations are not supported by all SCSI controllers.  

    WARNINGS

    The connectors on some SCSI devices do not conform to SCSI hotplug specifications. Performing hotplug operations on such devices can cause damage to the hardware on the SCSI bus. Refer to your hardware manual for additional information.


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    OPTIONS
    EXAMPLES
    FILES
    ATTRIBUTES
    SEE ALSO
    NOTES
    WARNINGS


    Поиск по тексту MAN-ов: 




    Партнёры:
    PostgresPro
    Inferno Solutions
    Hosting by Hoster.ru
    Хостинг:

    Закладки на сайте
    Проследить за страницей
    Created 1996-2024 by Maxim Chirkov
    Добавить, Поддержать, Вебмастеру